The segmented bend with its angle fixed at 90 degrees — the most common case in practice, with the angle field locked so it cannot be mistyped. Everything else works as the free segmented bend: you choose diameter, radius and gore count.
Direction changes in exhaust and ventilation ducting, large-diameter elbows fabricated from plate.
The values the form comes pre-filled with, run through the tool itself:
| Height | 1200 mm |
|---|---|
| Diameter | 800 mm |
| Angle | 90 mm |
| Sections | 3 mm |
| Divisions | 16 mm |
| Thickness | 10 mm |
| The flat pattern fits a plate of | 2482 × 427 mm |
| Flat patterns produced | 2 |